A beautiful exterior is only as dependable as the work beneath it. We plan roofing, siding, stucco and soft-metal installations around Alberta's applicable building requirements, the selected manufacturer's instructions, and careful attention to every detail.
Alberta Building Requirements
We reference the code and applicable local requirements for the work being done.
Manufacturer Installation Instructions
Each product is installed to its current approved system instructions.
Care in Every Layer
Water control, fastening, ventilation, finish and site cleanup all matter.
How we build with confidence
There is more to exterior protection than what you see.
Strong installation starts before the first shingle, siding panel or stucco coat is applied. Materials, substrate condition, moisture management and the details where different surfaces meet are all part of the system.
- 01 / ASSESS
Inspect the Existing Conditions
We review the condition of the roof deck or wall substrate and identify deteriorated areas, water entry points and conditions that need attention before covering them.
- 02 / PLAN
Match the Correct System
We confirm the selected product, approved accessories, installation method, roof slope or wall design and relevant code requirements for the specific project.
- 03 / PROTECT
Build the Water-Management Layers
We pay attention to underlayments, weather-resistive barriers, flashings and drainage paths before installing the visible finish.
- 04 / INSTALL
Follow Product-Specific Fastening
Fastener type, placement, spacing, penetration and allowance for material movement depend on the selected manufacturer's written instructions.
- 05 / DETAIL
Finish Critical Connections
Valleys, roof edges, openings, wall transitions, soffits and roof penetrations receive careful detailing for continuity and drainage.
- 06 / REVIEW
Inspect, Clean and Explain
We review visible work, address outstanding deficiencies, clean the work area and explain relevant care and warranty information at handover.
01 / Residential roofing
A roofing system, not just a layer of shingles.
For IKO and Malarkey shingle installations, the manufacturer's current application instructions guide the products and details we use. Alberta's building requirements and project conditions determine the additional protection required.
Installation checkpoints
- DECK PREPARATION
A sound foundation
Inspect the sheathing, repair damaged or unsound areas within scope, and start on a suitable, dry and secure roof deck.
- ICE & WATER CONTROL
Protection beneath the shingles
Use the specified roof underlayment and eave/valley ice-and-water protection, with laps and coverage suited to slope, product and code requirements.
- ROOF EDGES & VALLEYS
Correct flashing and sequencing
Integrate drip edges, starter courses and valley treatments so water sheds away from vulnerable transitions.
- NAILING ZONE
Fasteners in the right place
Use the correct nail type, count and placement in the designated nailing zone. Additional fastening is used where required by the selected shingle and roof conditions.
- PENETRATIONS & VENTILATION
Details that protect the home
Properly detail plumbing vents, chimneys, skylights, wall intersections, ridge caps and the roof ventilation system.
- FINAL CHECK
Inspect every finished section
Check visible alignment, fastening, edge treatments, flashing, site cleanup and any project-specific workmanship items.
02 / Siding & exterior cladding
Straight lines outside. Smart moisture protection behind.
Whether installing vinyl siding from Gentek, Mitten, Kaycan or Royal Building Products, or a specified fibre-cement (James Hardie) or engineered-wood (LP SmartSide) system, proper installation includes the wall assembly beneath the finish.
Installation checkpoints
- WALL PREPARATION
Level and sound surfaces
Check the substrate, sheathing, supporting structure and any required repairs before new cladding is applied.
- MOISTURE MANAGEMENT
Water is directed out
Install the applicable weather-resistive barrier, flashing and required drainage/air-space details as one coordinated wall assembly.
- OPENINGS & TRANSITIONS
Protect the vulnerable areas
Integrate window and door flashings, kick-out flashings, corners and roof-to-wall details with the drainage plane.
- FASTENING & MOVEMENT
Allow the material to perform
Follow the product-specific fastening schedule, slot placement, approved fasteners and expansion clearances rather than fastening panels too tightly.
- FINISHED APPEARANCE
Plumb, level and properly trimmed
Align starter strips, courses, corners, trim pieces and transitions for a clean, consistent finish.
- SOFFITS & ACCESSORIES
Keep the system connected
Coordinate soffit ventilation, fascia and accessories without blocking required airflow or trapping moisture.
03 / Stucco & exterior finishes
Stucco protection begins before the finish coat.
Traditional cement stucco and engineered EIFS assemblies are different systems. We follow the applicable Alberta cladding and stucco requirements and the selected system supplier's installation details rather than mixing incompatible components.
Installation checkpoints
- SUPPORT & PREPARATION
Proper substrates
Assess the surface and install the approved substrate preparation, lath or specified reinforcing system.
- WATER CONTROL
Drainage and flashing
Coordinate moisture barriers, drainage layers, window flashings and lower termination details where required by the wall assembly.
- APPLICATION
The right coats and sequence
Follow the specified mix, coat thickness, reinforcement, joint details, application conditions and curing requirements for the selected system.
04 / Soft metals & roof drainage
The small metal details make a big difference.
Eavestroughs, downspouts, fascia, soffits and flashings must work with the roof and wall systems to move water away from the home. Explore our soft metals services and the installation resources below.
Installation checkpoints
- EAVESTROUGHS
Consistent drainage
Install compatible, properly supported gutters with slope and outlet placement appropriate for the roof and building conditions.
- DOWNSPOUTS
Direct water away
Provide secure downspout routing and discharge that moves roof runoff away from vulnerable building areas.
- SOFFIT & FASCIA
Clean finish, clear airflow
Securely fasten and align metals while maintaining the intended roof ventilation and protecting exposed edges.
- FLASHINGS
Water-shedding transitions
Use correctly shaped, lapped and integrated flashings at roof edges, walls, penetrations and other interfaces.
- MATERIAL COMPATIBILITY
Appropriate fasteners and metals
Select compatible materials, finishes and corrosion-resistant fasteners as required by the project and product instructions.
- FINAL REVIEW
Secure, tidy and functional
Check supports, seams, outlet connections, water paths, sharp edges and overall finish before handover.
Every project deserves attention
Our four-stage installation review.
A practical workflow to help keep installation details visible, from the original condition of your home to the completed exterior.
- 01 BEFORE
Inspect & agree on scope
Confirm the existing condition, materials, expected details and any necessary repairs.
- 02 DURING
Check the hidden layers
Review barrier placement, protection details, deck or wall preparation and fastening practices.
- 03 FINISH
Review workmanship
Examine visible roof and cladding alignment, flashing, water-management details and cleanup.
- 04 HANDOVER
Explain what was done
Share relevant product information and available project documentation or warranty details.
Helpful documents from trusted sources
The official codes and installation guides we reference.
The current National Building Code – 2023 Alberta Edition (second printing, published August 2026) is Alberta's building code in force as of this page's preparation. For any job, use the current code, local authority requirements and the manufacturer's exact instructions for the product and installation conditions.
Relevant Part 9 code sections: 9.26 Roofing, 9.27 Cladding and 9.28 Stucco. Refer to the current adopted edition and any applicable STANDATA or project-specific requirements.
Building Code & Associations
Alberta Building Codes & Standards (official) NRC — National Building Code, Alberta Edition Alberta STANDATA — Building Code Updates Alberta Allied Roofing Association (AARA) Alberta Roofing Contractors Association (ARCA) Technical BulletinsRoofing Installation Guides
IKO — Shingle & Accessory Application Instructions IKO — Blueprint for Roofing Installation Malarkey — Current Installation Guides Malarkey — Architectural Laminate Shingle ManualSiding Manufacturers
Gentek — Siding, Soffit, Fascia & Rainware Mitten — Vinyl Siding & Cladding Kaycan — Vinyl, Soffit & Rainware Guides Royal Building Products — Siding Installation GuidesFibre Cement, Engineered Wood & Stucco
James Hardie — Fibre Cement Installation Guides LP SmartSide — Siding Application Instructions Sto Canada — Stucco SystemsImportant: This homeowner overview is not a technical specification, installation instruction or substitute for the current Alberta code, applicable permits, local authority requirements, engineered design or manufacturer directions. Actual requirements vary by the product, structure and site conditions. Links to associations and manufacturers are provided for reference and do not imply their endorsement of Nova Clad or of a particular project.
Quality is built into every layer.
Whether it is a roof replacement, new siding, stucco or soft-metal work, ask us about the installation details behind your quote.